Attachment and assembly

Type 8792, 8793

11.2.2 Attaching mounting bracket

Attach mounting bracket

to the back of the Type 8792/8793

with hexagon bolts

, circlip

and washers

(see “Fig. 9”).

The selection of the M8 thread used on the Type
8792/8793 depends on the size of the actuator.

To determine the correct position, hold the Type 8792/8793 with
mounting bracket on the actuator.

The conical roller

⑤ on the lever ⑥ of the position sensor must

be able to move freely in the hoop (refer “Fig. 9”) along the entire
stroke range of the actuator.
At 50% stroke the lever position should be approximately hori-
zontal (see chapter “11.2.3 Aligning lever mechanism”).

M8 thread

Legend:

No. Name
1

Mounting
bracket

5

Conical
roller

6

Lever

9

Hexagon
bolt

10 Circlip
11 Washer

Fig. 9:

Attaching mounting bracket

Attaching the Type 8792/8793 with mounting bracket for actu-
ators with cast frame:

Attach mounting bracket to the cast frame with one or more
hexagon bolts

, washers

and circlips

(see “Fig. 10”).

8 10 11 1

8

10

11

Legend:

No. Name
1

Mounting bracket

8

Hexagon bolt

10

Circlip

11

Washer

Fig. 10: Attach Type 8792/8793 with mounting bracket; for actuators with

cast frame