beautypg.com

7 pneumatic data – Burkert Type 8793 User Manual

Page 12

background image

12

Technical Data

Type 8792, 8793

Pt 100:

Measuring range -20 ... +220 °C
Resolution

< 0,1 °C

Measurement current < 1 mA

Input data for set-point value signal
0/4 ... 20 mA:

Input resistance 180 Ω
Resolution

12 bit

0 ... 5/10 V:

Input resistance 19 kΩ
Resolution

12 bit

Analogue feedback

max. current

10 mA
(for voltage output 0 ... 5/10 V)

Burden (load)

0 ... 560 Ω
(for voltage output 0/4 ... 20 mA)

Inductive proximity
switches

100 mA current limit

Binary outputs

galvanically isolated

Current limiting

100 mA, output is clocked if overload
occurs

Binary input

galvanically isolated
0 ... 5 V = log „0“, 10 ... 30 V = log „1“
inverted input in reverse order
(input current < 6 mA)

7.7 Pneumatic data

Control medium

Quality classes in accordance with DIN ISO
8573-1

Dust content

Class 5, max. particle size 40 µm, max. par-
ticle density 10 mg/m³

Water content

Class 3, max. pressure dew point - 20 °C or
min. 10 degrees below the lowest operating
temperature

Oil content

Class 5, max. 25 mg/m³

Temperature range
of compressed air

0 ... +60 °C

Pressure range

1.4 – 7 bar

Air flow rate

95 l

N

/ min (at 1.4 bar*) for aeration and

deaeration
150 l

N

/ min (at 6 bar*) for aeration and

deaeration
(Q

Nn

= 100 l

N

/ min (according to definition for

pressure drop from 7 to 6 bar absolute)).

Connections

Internal thread G1/4“

* Pressure specifications: Overpressure with respect to

atmospheric pressure

english