Technical data for the complete system – Burkert Type 8644 User Manual
Page 29
8644/phoenix - 25
S
YSTEM
D
ESCRIPTION
Technical data for the complete system
Voltage supply:
Rated voltage
24 V/DC
Tolerance
- 15% / + 20%
Valve types 0460, 0461
- 10% / + 10%
Current carrying capacity:
Contacts
max. 8 A
Valve block
max. 2.5 A
(via connector module left)
Maximum current consumption:
Logic current
I_Log = I_Log_FBKN +
Σ
I_Modul
I_Log
Current consumption logic range
I_Log_FBKN
proportional current in field bus nodes max. 1.25 A/DC
(0.75 A/DC for logic supply; 0.5 A/DC for analog voltage supply)
I_Module
proportional current logic range of the elec. base module max. 15 mA
I_Valve
Valve current - before and after power reduction
Valve type
Valve current
before power reduction
after power reduction
6524
43 mA
26 mA
6525
43 mA
26 mA
6526
96 mA
48 mA
6527
96 mA
48 mA
0460
38 mA
-
0461
38 mA
Temperature:
Storage temperature
- 20 to + 60 °C
Field bus nodes Profibus DP (standard)
0 to + 55 °C
Valve type 6524, 6525, 6526, 6527
0 to + 55 °C
Valve type 0460, 0461
0 to + 50 °C
NOTE
The admissible ambient temperature is depent on the modules used. During
assembly, the crucial factor is the most critical module.