Connection x, Drawing showing variants – Burkert Type 8644 User Manual
Page 100
96 - 8644/phoenix
S
YSTEM
D
ESCRIPTION
Connector modules, pneumatic - middle, type ME02
Variants
Drawing showing variants
Intermediate supply
Pneumatic connections
Manometer
Cover
G 1/4
M 5
G 1/4
D 10
D 4
D 10
NPT 1/4
M 5
NPT 1/4
Supply port (P) 1
Connection X
Exhaust port (R/S) 3/5
without manometer
G ¼
M5
G ¼
D 10
D 4
D 10
NPT ¼
M5
NPT ¼
with manometer
G ¼
M5
G ¼
D 10
D 4
D 10
NPT ¼
M5
NPT ¼
Operating mode
Configuration of X
Standard
Exhaust air from pilot valve
Auxiliary control air
Connection for auxiliary control air
Operation with auxiliary control air is optional
Connection X