Maintenance, cleaning

note!

damage to the seat seal or the seat contour!

▶ When installing the actuator, ensure that the valve is in open

position.

control function a:
Without unit control: pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
With unit control: open the valve according to the operating
instructions for the control unit.

Screw actuator into the valve body.
Observe tightening torque (see “Tab. 11: Tightening torques of
valve body / nipples”
).

1

2

Pilot air port

Fig. 19: Connections

tightening torques of valve body / nipples
dn

tightening torques [nm]

10/15

45 ±3

20

50 ±3

25

60 ±3

32

65 ±3

40
50

70 ±3

65

100 ±3

80

120 ±5

100

150 ±5

Tab. 11: Tightening torques of valve body / nipples

If the position of the pilot air ports for installation of the hoses
is unfavorable, these can be aligned steplessly by rotating
the actuator through 360°.
The procedure is described in the chapter entitled “8.3.4
Rotating the actuator”.