beautypg.com

English – Burkert Type 2301 User Manual

Page 16

background image

16

Technical data

Designs with lower pilot pressure (reduced spring force)
are available on request.
Contact your Bürkert sales office or our Sales Centre.
E-mail: [email protected]

required minimum pilot pressure depending on medium
pressure for circuit function B

DN20

DN25

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

7

8

9

10

DN10/15

pilot pressure [bar]

m

edium

pressure

[bar]

ø 50 cfB

Fig. 3: Pressure graph, actuator ø 50 mm, control function B

DN2

0

DN25

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

7

8

9

10

DN10/15

pilot pressure [bar]

m

edium

pressure

[bar]

ø 70 cfB

Fig. 4: Pressure graph, actuator ø 70 mm, control function B

DN3

2

DN50

0

2

4

6

8

10

12

14

16

0

1

2

3

4

5

6

7

8

9

10

DN2

5

DN4

0

pilot pressure [bar]

m

edium

pressure

[bar]

ø 90 cfB

Fig. 5: Pressure graph, actuator ø 90 mm, control function B

english

Type 2301