beautypg.com

Burkert Type 2301 User Manual

Page 15

background image

15

Technical data

Operating pressure for control function a

7)

actuator
size
[mm]

connection
size[mm]

required pilot
pressure [bar]

max. sealed medium

pressure [bar]

steel/steel ptfe/steel

ш 50

4 – 6

5.5

16

-

8 – 15

5.5

16

16

20

5.5

10

10

25

5.5

5

5

ш 70

4 – 6

5.5

16

-

8 – 20

5.5

16

16

25

5.5

12

12

ш 90

25 – 32

5.5

16

16

40

5.5

12

12

50

5.5

7

7

ш 130

32 – 50

5.5

16

16

65

5.6

16

16

80

5.6

10

10

100

5.6

6

6

Tab. 5: Operating pressure for control function A

7)

The description of the control function (CF) can be found in
chapter entitled “6.2.1 Control functions (CF)”.

pilot pressure for control function B

8)

actuator
size

connection
size [mm]

pilot pressure [bar]

max. per-
mitted
medium
pressure
[bar]

for medium pressure

0 bar

max

ø 50 mm

4 – 15

5.1

7.0

16

20

5.1

7.0

9

25

5.1

7.0

5

ø 70 mm

4 – 15

5.2

6.2

16

20

5.2

6.8

16

25

5.2

7.0

12

ø 90 mm

25

2.4

4.2

16

32

2.5

5.3

16

40

2.5

6.5

16

50

2.5

7.0

14

ø 130 mm

32

2.7

4.0

16

40

2.7

4.5

16

50

2.7

5.6

16

65

2.7

7.0

16

80

2.7

7.0

10

100

2.7

7.0

6

Tab. 6: Pilot pressure for control function B

8)

The description of the control function (CF) can be found in
chapter entitled “6.2.1 Control functions (CF)”.

english

Type 2301