beautypg.com

5 removal, 9 electrical control unit, 10 maintenance, cleaning – Burkert Type 2301 User Manual

Page 28: 1 safety instructions, 9electrical control unit

background image

28

Maintenance, cleaning

8.5

removal

Danger!

risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.

▶ Before removing a device, switch off the pressure and vent the

lines.

procedure:

Loosen the pneumatic connection.

Remove the device.

9

elecTrical cOnTrOl uniT

The valve Type 2301 can be combined with following control units:
• Type 8692

Positioner

• Type 8694

Positioner

• Type 8696

Positioner

• Type 8693

Process controller

The electrical connection of the pilot valve or the control
unit is described in the respective operating instructions for
the pilot valve/control unit in the chapter titled “Installation”.

10

mainTenance, cleaning

10.1 safety instructions

Danger!

danger – high pressure in the equipment!

▶ Before loosening the lines and valves, turn off the pressure and

vent the lines.

risk of injury due to electrical shock!

▶ Before reaching into the system, switch off the power supply

and secure to prevent reactivation!

▶ Observe applicable accident prevention and safety regulations

for electrical equipment!

Warning!

risk of injury from improper maintenance!

▶ Maintenance may be performed by authorised technicians only!

▶ To screw on or unscrew valve body or actuator, use an open-

end wrench, never a pipe wrench, and observe tightening

torques.

risk of injury from unintentional activation of the system and
an uncontrolled restart!

▶ Secure system from unintentional activation.

▶ Following maintenance, ensure a controlled restart.

english

Type 2301