beautypg.com

Of valve body / nipples – Burkert Type 2301 User Manual

Page 24

background image

24

Installation

Other body versions

Connect body to pipeline.

8.3.2 install actuator (welded body)

Graphite seal

Fig. 10: Graphite seal

Check the graphite seal and if required, replace it.

Warning!

danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen appli-
cations there is a risk of an explosion!

▶ In specific applications, e.g. oxygen or analysis applications, use

appropriately authorized lubricants only.

Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).

note!

damage to the seat seal or the seat contour!

▶ When installing the actuator, ensure that the valve is in open

position.

Control function A pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.

Screw actuator into the valve body.
Observe tightening torque (see “Tab. 10”).

1

2

Pilot air port

Fig. 11: Connections

tightening torques of valve body / nipples
dn

tightening torque [nm]

10/15

45 ±3

20

50 ±3

25

60 ±3

32

65 ±3

40
50

70 ±3

65

100 ±3

80

120 ±5

100

150 ±5

Tab. 10: Tightening torques of valve body / nipples