Part 4 - software utilities – Dynasonics MFX Series Insertion MagProbe Flow Meter User Manual

Page 56

background image


Rev. 01/11

-4.4-

MFX

x Liner Thickness (entry becomes available when a Liner

Material is selected) enter this value in inches for English units or
millimeters for Metric units.

x Fluid Type does not pertain to the MFX product.


2. FLOW TAB - see Figure 4.3
x Flow Rate Units are selected from the pull-down lists. Select an

appropriate rate unit and time from the two lists.

x Totalizer Units are selected from pull-down lists. Select an

appropriate totalizer unit and totalizer exponent. The totalizer
exponents are in Scientific Notation and permit the eight digit
totalizer to accumulate very large values before the totalizer
“rolls over” and starts again at zero. Table 4.1 on page 4.5
illustrates the Scientific Notation values and their respective
decimal equivalents.

x MIN Flow is used by the MFX to establish filter settings in its

operating system. Enter a flow rate that is the minimum flow rate
anticipated within the system. For unidirectional systems, this
value is typically zero. For bi-directional systems this value is set
to a negative number that is equal to the maximum negative flow
rate that is anticipated within the system.

PART 4 - SOFTWARE UTILITIES

Flow Units
Configuration

Figure 4.3

Flow Tab