ALLIED Vision Technologies Bonito CL-400 200 fps User Manual
Page 78

Appendix
Bonito Technical Manual V2.3.0
78
All other values are reserved.
T=
0: None.
2: OK1 at control connector.
3: CC1 at O2 connector (or CL1).
4: CC1 at O4 connector (if available).
All other values are reserved.
U=
<***t_***m>
| |
| +-m: Metadata overlay mode.
| 0: No overlay.
| 1: Show metadata in each frame starting at
| the first pixel of the first line.
+------t: Test image generator.
0: Normal image output.
1: Test image generator is active.
V=1 : Show model and firmware version information. Use V=2 for a
more detailed output.
W=
is used to adjust the dark level and avoid clipping of pixels
to black in low light situations. The eight bits are aligned
to the lowest significant bit of the 10-bit raw pixel data
from the sensor. if the digital gain is not active
(G=0), each increment of four increases the output grey level
just for one count.
X=1 : Store the current parameter configuration to the flash.
Y=1 : Show the current parameter configuration.
Z=1 : Load the factory default parameter configuration. The
saved configuration is only affected if you store the reset
parameter values with X=1 afterwards.