background image

Parameters and commands

Bonito Technical Manual V2.3.0

38

Parameters and commands

This section explains the basic Bonito configuration parameters and general
commands available to the user. Parameters and commands are communicated
using the camera’s serial interface. For more information see chapter

Serial I/O

on page 22.

Primary starting address (A)

The parameter

A defines the line address of the image sensor that is the first

line of the output image. The value of

A in conjunction with N and I is used to

create a region of interest (ROI1).

Range

From

0 (topmost line) to 6BD (lowermost line)

Default

0

Related

Parameters

B, D, N and I

Example

A=35E

(0x35E = 862), first line at address 862, that is the 863

rd

line of the

sensor

N=F

read 16 lines

I=2

read every second line

Note

In this section, all values and examples noted in

mono-

spaced font are denoted in the hexadecimal numbering
system, if not otherwise noted.

In all cases, explicit base notation (e.g. 0x4711 or 045H) is
omitted to be directly compatible to the camera's command
interface syntax.

Example: to set

M to the value of M=0x21,

use the command

M=21.

Note

For more information on double ROI mode and a diagram dis-
playing the ROI parameters, see chapter

Double region of

interest mode (D)

on page 40.

Each image sensor line can only be read once per exposure. Two
ROIs are only possible as long as they do not share the same
line addresses.