ALLIED Vision Technologies Bonito CL-400 200 fps User Manual
Page 67

Parameters and commands
Bonito Technical Manual V2.3.0
67
To set a sub-field to a certain value, modify the associated bit group by allocat-
ing
s to the appropriate hexadecimal number.
Since all of the sub-fields are set using the parameter
s, it is only possible to set
all of them at the same time. The value of
s is calculated as the aggregate sum
of the hexadecimal values that are set to each of the three sub-fields.
The table below shows the hexadecimal values that can be set for each sub-
field. To work out the final value for
s, select the usage for each sub-field, then
add the corresponding hexadecimal values.
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
-
-
-
-
-
-
-
-
e
a
a
-
x
x
x
x
-
-
-
-
-
-
-
- rw rw rw
rw rw rw rw
Table 27: Order of bit groups within parameter
s
Bit values
Settings
Weight
(hexadecimal)
Baud rate of the serial ports
xxx-0000 110 Baud *
0
xxx-0001 300 Baud *
1
xxx-0010 600 Baud *
2
xxx-0011 1,200 Baud *
3
xxx-0100 2,400 Baud *
4
xxx-0101 4,800 Baud *
5
* Baud rates up to 4,800 Baud are not available via Camera Link.
xxx-0110 9,600 Baud
6
xxx-0111 19,200 Baud
7
xxx-1000 38,400 Baud
8
xxx-1001 57,600 Baud
9
xxx-1010 115,200 Baud
A
Enable state of the serial ports
x00-xxxx RS232 via 15-pin D-sub connector only.
0
x01-xxxx Additionally activates second channel via
Camera Link connector O2.
20
x10-xxxx Additionally activates second channel via
Camera Link connector O4.
40
x11-xxxx Additionally activates second channel via
Camera Link connector O2 and O4.
60
Table 28: Baud rate: hexadecimal weights for each setting