Exposure time (e) – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual
Page 41

Parameters and commands
Bonito Technical Manual V2.3.0
41
The diagram illustrates the use of ROI parameters
A, B, I, and N, from the sen-
sor’s point of view. The sensor’s first (topmost) line has the address
0, the last
(lowermost) line has the address
6BD.
Range
0 (=off)or 1 (=on)
Default
0
Related
Parameters
A, B, D, N and I
Example
A=0
start first AOI at the first line
B=5BD
(0x5BD = 1469), starts second AOI at the 1470
th
line
D=1
enable double ROI mode
N=FF
(0xFF = 255), reads 256 lines from each ROI, 512 lines in the out-
put image
I=1
read every line
Result: lines no 0 to 255 and no 1469 to 1724 of each image are read.
Exposure time (E)
The exposure time is a 32-bit value. Its time resolution depends on the prescaler
value
K. For detailed information see chapter
Technically, the value range is 32 bit, whereas the useful exposure times should
be up to approx. 1 second.
Range
Useful from
1 to approx. 50000 at K=A7, but not limited to that maximum.
Default
6BE (=1726)
Figure 23: Parameters relevant in double ROI mode