Synchronization output (j), Dded chapter, E chapter – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual
Page 44: Synchronization output

Parameters and commands
Bonito Technical Manual V2.3.0
44
Related
Parameters
A, B, D, and N
Example
I=4
output every 4
th
line
N=1AF
(0x1AF = 431), sets number of lines to 431, which equals a quarter
of the full image
Synchronization output (J)
Parameter
J sends an output synchronization signal to pin 6 of the camera con-
trol connector.
Valid values:
Either one of the values
0, 1, 2, 3, 8, 9, A, B
Default
1
Related
Parameters
D, E, F, M, N and S
Setting
Output signal
J=0
Effective sensor exposure
J=1
Charge transfer pulse
Active for one line duration at the end of exposure. End of this
pulse marks the end of exposure and at the same time start of sen-
sor readout.
In PIV mode: this pulse occurs at the exposure end of only the first
image of each PIV pair. For more information see chapter
J=2
Effective sensor readout
J=3
Exposure phase
Contrary to
J=0, this setting shows the exposure phase of the
internal state machine and not the effective exposure of the sen-
sor. This allows to synchronize external devices even if the sensor
is in permanent exposure mode. For more details see chapter
J=8
Same as
J=0, but with inverted logic on sync output
J=9
Same as
J=1, but with inverted logic on sync output
J=A
Same as
J=2, but with inverted logic on sync output
J=B
Same as
J=3, but with inverted logic on sync output
Table 7: Synchronization output