Trigger source selection (t) – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual
Page 61

Parameters and commands
Bonito Technical Manual V2.3.0
61
Trigger source selection (T)
This parameter selects the signal source for triggering and exposure control.
For more information about usage of the selected signals: see chapter
Range
Either
0, 2, 3, or 4
Default
3
Related
Parameter
M
Example
T=2
Select the optocoupler input at pins 10 and 11 of the I/O connec-
tor as trigger source
S=1
•
Mode: Dual channel mode (not for Bonito CL-400B/C
200fps)
•
Frame rate: 386 fps
•
Line length: 2 x 1160 = 2320 pixels
The image is split vertically into a left and a right half. Each half
has a horizontal size of 1160 pixels and is output separately via
its own Camera Link 80-bit channel. The left half travels via the
left Camera Link channel at the connectors O2 / O1 and the right
half travels via O4 /O3 respectively.
S=3
•
Mode: Dual channel mode (not for Bonito CL-400B/C
200fps)
•
Frame rate: 386 fps
•
Line length: 2 x 1120 = 2240 pixels
This mode is the same as
S=1, with the difference of a shortened
line length. For frame grabber compatibility reasons 40 pixel col-
umns at the left and right side of the full image are dropped so
that the line length of each image half is divisible by 16.
S=5
Same as
S=1, but with right image half via O2/O1 and left image
half via O4/O3 (if available).
S=7
Same as
S=3, but with right image half via O2/O1 and left image
half via O4/O3 (if available).
(Others)
Reserved for future use.
Setting
Function
Table 22: Camera Link output settings.