beautypg.com

Trigger input (pin 10-11), Exposure output (pin 12-13), N chapter – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 27

background image

Camera interfaces

Bonito Technical Manual V2.3.0

27

Trigger input (pin 10-11)

The current through the optocoupler’s LED should be in the range from 5 mA to
15 mA. This is the case if 5.0 V ≤ V

in

≤ 12 V.

A rising edge at this optocoupler input starts the exposure. It depends on the
trigger input selection T and the current trigger mode M whether this input is
enabled and how it controls the exposure time.

The optocoupler adds a typical delay of about 0.1 μs to the externally applied
signal.

For more information on the various trigger and exposure modes: see chapter

Exposure control mode (M)

on page 45.

Exposure output (pin 12-13)

Figure 11: Trigger input diagram

Note

If you use higher voltages, you have to connect externally an
additional current limiting resistor.

Figure 12: Exposure output

This manual is related to the following products: