Serial control interface configuration (s), See chapter – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual
Page 66

Parameters and commands
Bonito Technical Manual V2.3.0
66
Serial control interface configuration (s)
Use parameter
s to set up the serial control interface of the camera, such as
baud rate, enable state, or echo mode.
Range
From
0 to FFFF.
Since the parameter
s is divided into three different sub-fields (see further
below), the following ranges cover all possible uses of this parameter. It is rec-
ommended not to use parameters that are outside the defined ranges.
0 to A, 20 to 2A, 40 to 4A, 60 to 6A, 80 to 8A, A0 to AA, C0 to CA, E0 to EA.
Default
2A (115,200 Baud, additionally activates second channel via Camera Link con-
nector O2, each character received from the host is echoed back to it.)
Related
Three sub-fields are available to control the serial control interface, of the
Bonito CL-400B/C:
•
Baud rate of the serial ports
•
Echo mode
•
Enable state of the serial ports
All of these sub-fields are controlled by the parameter
s, however, each of them
works independently from the other sub-fields. The sub-fields are represented
by bit groups of different size within the parameter
s.
4022
4064022
Bonito CL-400B EF-Mount 200fps
4030
4064030
Bonito CL-400C 200fps
4031
4064031
Bonito CL-400C F-Mount 200fps
4032
4064032
Bonito CL-400C EF-Mount 200fps
4100
4064100
Bonito CL-400BS
FFFF
-
Unknown / test / prototype
Bit group
Sub-field description
x
Controls the baud rate of the serial ports.
a
Controls the enable state of the serial ports.
e
Controls the echo mode.
Table 26: Attribution of bit groups and sub-fields
b
Article number
Camera variant
Table 25: Product variant code (b)