8 programming, 9 speed control, Programming – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual
Page 8: Speed control
8
IM-pAC Getting Started Guide
www.camcoindex.com | www.destaco.com
Issue Number: 5
1.8
Programming
The IM-pAC drive is delivered to you programmed for the 1/3 hp 230V 60 hz motor (IMC
Pt. No 92C49952070000). For a different motor rated frequency, amperage, voltage or
power factor you must change the motor parameters Pr 39, Pr 06, Pr 08 and Pr 09.
Below is a chart of the values for all the possible configurations of the standard IMC
motors. If you are not using an IMC motor then you must read these values from the
motor name plate
. See section 6.3 Selecting and changing parameters on page 47 for
how to edit the parameter values.
1.9
Speed Control
You must now determine how you wish to control the maximum speed for your
application.
You can use a single preset speed parameter, or use an external potentiometer, or use
a potentiometer and 3 other preset speeds, or use a PLC to control speed. Please refer
to one of the four parameter list sections for the additional parameter changes for the
speed control you require for your application.
T1
T2
T3
T4
T5
T6
B1
B2
B3
B4
B5
B6
B7
Drive enabled (normally closed)
Stop signal switch on camshaft
(normally closed)
Momentary Start
Radio Shack Pt.No 275-324
IMC Pt.No 87C08062019510
Radio Shack Pt.No 275-609
hp
kw
IMC Motor
Frequency
Pr 39
hz
Current
Pr 06
amp
Rpm
Pr 07
Voltage
Pr 08
volt
Power
factor
Pr 09
cos
∅
0.33
0.25
92C49952070000
60
1.14
0
230
0.74
0.33
0.25
92C49952070000
60
0.57
460
0.74
0.33
0.25
92C49952070000
50
1.14
200
0.74
0.33
0.25
92C49952070000
50
0.57
400
0.74
1.00
0.75
92C49955410000
60
3.15
230
0.79
1.00
0.75
92C49955410000
60
1.9
460
0.66
1.00
0.75
92C49955410000
50
3.65
200
0.70
1.00
0.75
92C49955410000
50
2.1
400
0.70
Never auto tune the motor