3 rating data, Rating data, Refer to chapter 3 rating data – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual
Page 35: 3rating data
IM-pAC Getting Started Guide
35
Issue Number: 5
www.camcoindex.com | www.destaco.com
Re
Sa
Ra
tin
Me
ch
Ele
n
Ke
Par
D
UL
Li
3
Rating Data
Table 3-1 120V drive
Table 3-2 200V drive
Table 3-3 400V drive
Model Number
Nominal
Motor Power
Supply voltage
and frequency
Typical
full load
input
current
A
100% RMS
output
current
A
150%
overload
current for
60s
A
Minimum
braking
resistor
value
Ω
hp
kW
1ph
Heavy Duty
92B90482070000 1.0 0.75
1 phase
100 to 120V ±10%
48 to 62 hz
19.6
4
6
28
92B90482080000 1.5 1.1
1 phase
100 to 120V±10%
48 to 62 hz
24
6
7.8
28
Model Number
Nominal
Motor Power
Supply voltage
and frequency
Typical
full load
input
current
A
100% RMS
output
current
A
150%
overload
current for
60s
A
Minimum
braking
resistor
value
Ω
hp
kW
1ph
Heavy Duty
92C85797010000
1.0
0.75
1 phase
200 to 240V ±10%
48 to 62 hz
10.5
4.0
6.0
68
92B90482010000 1.5 1.1
1 and 3 phase
200 to 240V ±10%
48 to 62 hz
14.2 16.7
5.2
7.8
28
92B90482020000 2.0 1.5
1 and 3 phase
200 to 240V ±10%
48 to 62 hz
17.4 8.7
7.0
10.5
28
92B90482030000 3.0 2.2
1 and 3 phase
200 to 240V ±10%
48 to 62 hz
23.2 11.9
9.6
14.4
28
Model Number
Nominal
Motor
Power
Supply voltage
and frequency
Typical
full load
input
current
A
Maximum
continuous
current
A
100%
RMS
output
current
A
150%
overload
current
for 60s
A
Minimum
braking
resistor
value
Ω
hp
kW
3ph
Heavy Duty
92C85797020000 1.0
0.75
3 phase
380 to 480V ±10%
48 to 62 hz
3.1
3.75
2.1
3.2
100
92B9048209000 1.5 1.1
3 phase
380 to 480V ±10%
48 to 62 hz
4
4.6
2.8
4.2
100
92B90482040000 2.0 1.5
3 phase
380 to 480V ±10%
48 to 62 hz
5.2
5.9
3.8
5.7
100
92B90482050000 2.2 3
3 phase
380 to 480V ±10%
48 to 62 hz
7.3
9.6
5.1
7.65
100
92B90482060000 4
5
3 phase
380 to 480V ±10%
48 to 62 hz
11.9
13.4
9.0
13.5
55