3 parameter descriptions - level 3, 4 diagnostic parameters, Parameter descriptions - level 3 – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual
Page 66: Diagnostic parameters
66
IM-pAC Getting Started Guide
www.camcoindex.com | www.destaco.com
Issue Number: 5
7.3
Parameter descriptions - Level 3
Set Pr 71 to Pr 80 to the required advanced parameter number to be accessed.
The value within these parameters will be displayed in Pr 61 to Pr 70. Pr 61 to Pr 70 can
then be adjusted to change the value within a parameter.
7.4
Diagnostic parameters
The following read only (RO) parameters can be used as an aid to fault diagnosis on the
drive. See Figure 8-1 Diagnostics logic diagram on page 68.
No
Function
Range
Defaults
Type
71
to
Pr
61
to Pr
70
set up
0 to Pr 21.51
RW
80
No
Function
Range
Type
81
Frequency reference selected
±Pr 02 Hz
RO
82
Pre-ramp reference
±Pr 02 Hz
RO
83
Post-ramp reference
±Pr 02 Hz
RO
84
DC bus voltage
0 to Drive maximum VDC
RO
85
Motor frequency
±Pr 02 Hz
RO
86
Motor voltage
0 to Drive rating V
RO
87
Motor speed
±9999 rpm
RO
88
Motor current
+Drive maximum A
RO
89
Motor active current
±Drive maximum A
RO
90
Digital I/O read word
0 to 95
RO
91
Reference enabled indicator
OFF (0) or On (1)
RO
92
Reverse selected indicator
OFF (0) or On (1)
RO
93
Jog selected indicator
OFF (0) or On (1)
RO
94
Analog input 1 level
0 to 100 %
RO
95
Analog input 2 level
0 to 100 %
RO