26 drive wiring for a motor reversing application, Drive wiring for a motor reversing application – DE-STA-CO IM-pAC AC Drive Getting Started Guide User Manual
Page 27
![background image](/manuals/322024/27/background.png)
IM-pAC Getting Started Guide
27
Issue Number: 5
www.camcoindex.com | www.destaco.com
Re
a
Sa
R
Me
ch
Ele
n
Ke
Par
D
UL
Li
1.26
Drive wiring for a motor reversing application.
Diagram for wiring switches to the IM-pAC control terminals (cover has been removed)
for cycling on demand using a limit switch, momentary start and inverter duty motor.
Index drive is in middle of dwell position see section 1.16 Indexer drive shown in middle
of dwell position diagram on page 10.
T1
T2
T3
T4
T5
T6
B1
B2
B3
B4
B5
B6
B7
Drive enabled (normally closed)
Momentary Start
Radio Shack Pt.No 275-324
Radio Shack.Pt.No 275-609
Stop signal switch on camshaft
(normally closed)
IMC Pt.No 87C08062019510
Forward / Reverse
You must provide the logic which will open and close the B2-B6 terminals.
Opening or closing the B2-B6 terminals with parameter Pr set to 2 will reverse
the motor direction for the next move.
There must be two limit switch cams mounted to signal the motor stop for the
middle of dwell,
one for the forward motion and the other for the reverse, see below.