beautypg.com

Atec Agilent-E5071B User Manual

Page 32

background image

32

Table 3-2

Option E5092A-020 port performance (continued)

Description Specification Typical

Load match (common port)

SPDT switch

1

50 MHz to 2 GHz

16 dB

2 GHz to 4 GHz

11 dB

4 GHz to 8 GHz

8 dB

8 GHz to 10 GHz

7 dB

10 GHz to 20 GHz

4 dB

SP4T switch

2

50 MHz to 1.3 GHz

16 dB

1.3 GHz to 4 GHz

11 dB

4 GHz to 8 GHz

8 dB

8 GHz to 10 GHz

7 dB

10 GHz to 20 GHz

4 dB

Insertion loss

SPDT switch

1

50 MHz to 100 MHz

4 dB

100 MHz to 2 GHz

3.5 dB

2 GHz to 3 GHz

4.5 dB

3 GHz to 4 GHz

5 dB

4 GHz to 6 GHz

5.5 dB

6 GHz to 8 GHz

7 dB

8 GHz to 10 GHz

8 dB

10 GHz to 14 GHz

8.5 dB

14 GHz to 18 GHz

10 dB

18 GHz to 20 GHz

11.5 dB

SP4T switch

2

50 to 100 MHz

4 dB

100 MHz to 2 GHz

3.5 dB

2 GHz to 3 GHz

4.5 dB

3 GHz to 4 GHz

5.5 dB

4 GHz to 6 GHz

6 dB

6 GHz to 8 GHz

7.5 dB

8 GHz to 10 GHz

8.5 dB

10 GHz to 14 GHz

9.5 dB

14 GHz to 18 GHz

10.5 dB

18 GHz to 20 GHz

12 dB

Stability

50 MHz to 6 GHz

0.003 dB/°C

6 GHz to 20 GHz

0.01 dB/°C (Stability per switch)

Isolation

3

50 MHz to 500 MHz

65 dB

500 MHz to 1 GHz

80 dB

1 GHz to 2 GHz

85 dB

2 GHz to 6 GHz

90 dB

6 GHz to 10 GHz

85 dB

10 GHz to 18 GHz

75 dB

18 GHz to 20 GHz

65 dB (Over arbitrarily test ports)

1

SPDT: Single-pole-double-throw switches. Applies to SW5, SW6, SW7, SW8, SW9 and SW10 in the E5092A. (See Figure 3-5.)

2

SP4T: Single-pole-four-throw switches. Applies to SW1, SW2, SW3 and SW4 in the E5092A. (See Figure 3-5.)

3

This specification is defined when all ports are terminated with a 50 ohm load.