53 generic power supply options – Alpha Technologies XP-EDH4 - Technical Manual User Manual
Page 30

30
745-419-B0-001 Rev. A (11/2013)
Installation Procedure:
1. Remove the EDH4 transponder and cabling hardware from its shipping package.
2. Open the power supply cabinet using the manufacturer’s recommended procedures.
3. Insert the 16-pin connector of the EDH4 Power Supply Interface Cable into the transponder’s PWR
SUPPLY interface port.
4. Install the EDH4 into the power supply cabinet using the adhesive fasteners on the bottom of the
transponder. Refer to Figure 2-12 for a possible mounting location in the enclosure.
5. Insert the power supply interface cable into the status monitoring connector of the power supply
(see Fig. 2-13). See the power supply manufacturer’s operating manual for information on the power
supply.
Required Materials
RF Cable
Customer supplied
Power Suppy Interface
Alpha p/n 875-335-25 (Generic)
Battery Sense Wire Harness for:
36V single string, 6', Alpha p/n 874-842-21
36V single string, 9', Alpha p/n 874-842-27
36V dual string, 9', Alpha p/n 874-842-28
48V single string, 9', Alpha p/n 874-841-25
48V dual string, 9', Alpha p/n 874-841-24
Battery Heater Mat Control Cable
Alpha p/n 875-627-20
Ethernet Cable (optional)
Alpha p/n 875-734-19
External Temperature Probe (optional)
Alpha p/n 745-178-21
Vin Sense (optional; requires 120VAC receptacle)
Alpha p/n 875-493-21
Surge Protector w/Ground Block
Alpha p/n 162-028-10
Vout / lout Sense Harness
NOTE: On-site modifications may be required in order to
interface with undocumented power supply types.
Alpha p/n 875-456-10
Tamper Wire Harness
NOTE: On-site modifications may be required in order to
interface with undocumented power supply types.
Alpha p/n 875-494-20
In Line Lightning Arrestor w/pass thru (130V) L-G, L-N, N-G Alpha p/n 162-046-10 (not compatible with
240V circuits / receptacles)
Fig. 2-14, Installing the EDH4
2.0
Installation, continued
2.53 Generic Power Supply Options