Doc. #: 0260011-J0 Rev B
2.6.2 Multiple Connections
Since the CXCU controller only has one port, a switch must be used for the following requirements:
• Simultaneous display at the graphic display and a local laptop
• Local display at the graphic display and remote Simple Network Management Protocol (SNMP) /
Ethernet functionality
Alpha Technologies has tested the Netgear JFS516 network switch, but network switches with the following
functionality will work:
• Network Interface: RJ-45 connector for 10BASE-T or 100BASE-TX Ethernet interface
• Meets IEEE 802.3i 10BASE-T Ethernet, IEEE 802.3u,100BASE-TX Fast Ethernet
• Meets IEEE 802.3x Flow Control; compatible with Windows®
Figure 10 — Multiple network connections to the CXCU
PC running IE8.0
or Firefox
10. 10. 10. 202
255. 255. 255. 0
http://10.10.10.201/
Obtain an IP Address Using DHCP
Use the following IP Address
Default Gateway:
Subnet Mask:
IP Address:
Cancel
Apply
Application Settings
CXC Connection Settings
IP Protocol Settings
Connection Status
Graphic Display
IE7.0 or greater
or Firefox
Router or switch
Ethernet
connector
CXCU
Ethernet
Ethernet
PC running
Remote Network
Access