Parameters – Elmo Rietschle 2FC4...-1CB User Manual
Page 54

7
Parameters
610.00260.40.000 · 05.2014
54
/
74
© Gardner Denver Deutschland GmbH
5.070
Motor current limit
Unit: %
Relationship to
parameter:
5.071
33.031
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 250
Def: 0
0 = disabled
5.071
Motor current limit
Unit: s
Relationship to
parameter:
5.070
33.031
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 100
Def: 1
5.075
Transmission factor
Unit:
Relationship to
parameter:
33.034
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 10000
Def: 1
Here, a transmission factor can be set.
With the help of the transmission factor, the display of the me-
chanical speed can be adapted.
Blocking detection
5.080
Blocking detection
Unit: Integer
Relationship to
parameter:
5.081
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 1
Def: 0
Using this parameter, the blocking detection can be enabled.
0 = inactive
1 = active
5.081
Blocking time
Unit: s
Relationship to
parameter:
5.080
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 50
Def: 2
Specifies the time after which a blocking is detected.
5.090
Change in the parameter set
Unit: Integer
Relationship to
parameter:
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 7
Def: 0
Selection of the active record.
0 = not assigned
1 = record 1, active
2 = record 2, active
3 = digital input 1
4 = digital input 2
5 = digital input 3
6 = digital input 4
7 = integrated soft - PLC
. The second record is displayed on the PC software only if this
parameter is <> 0. The values of the currently selected record
are shown on the display of the hand-held unit.
7.3.12