Parameters – Elmo Rietschle 2FC4...-1CB User Manual
Page 50

7
Parameters
610.00260.40.000 · 05.2014
50
/
74
© Gardner Denver Deutschland GmbH
Analogue output
4.100
AO1 function
Unit: Integer
Relationship to
parameter:
4.101
4.102
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 40
Def: 5
Selection of the process value that is output at the analogue
output.
Depending on the process value selected, the standard
(4,101/4,102) must be adapted.
0 = not assigned / DRIVE CONTROLLER soft PLC
1 = intermediate circuit voltage
2 = mains voltage
3 = motor voltage
4 = motor current
5 = actual frequency
6 = speed measured externally by speed sensor (if available)
7 = current angle or position (if available)
8 = IGBT temperature
9 = inner temperature
10 = analogue input 1
11 = analogue input 2
12 = rated frequency
13 = motor power
14 = torque
15 = field bus
16 = PID setpoint (above V3.60)
17 = PID feedback (above V3.60)
4.101
AO1 Norm. Low
Unit:
Relationship to
parameter:
4.100
Parameter HB:
S. xy
Transfer
status:
2
min: -10000
Intrinsic value
(to be en-
tered!)
max: +10000
Def: 0
Describes the range to be resolved to the output voltage 0 - 10
V or output current 0 - 20mA.
4.102
AO1 Norm. High
Unit:
Relationship to
parameter:
4.100
Parameter HB:
S. xy
Transfer
status:
2
min: -10000
Intrinsic value
(to be en-
tered!)
max: +10000
Def: Type-
specific
Describes the range to be resolved to the output voltage 0 - 10
V or output current 0 - 20mA.
7.3.7