Commissioning
6
© Gardner Denver Deutschland GmbH
35
/
74
05.2014 · 610.00260.40.000
4. Perform motor identification.
5. Implement
application
settings (ramps, inputs, outputs, setpoints, etc.).
6. Optional: Define access level (1 - HAND-HELD UNIT MMI, 2 - user 3 - manu-
facturer).
7. Once all settings have been implemented, with a high signal on terminal strip
X5 through the hardware release (En-HW) on terminal no. 10 and software re-
lease on terminal no. 6 (digital input 1), the drive control can be put into op-
eration (e.g. control via analogue input 1 with 0-10 V).
For an optimum operating structure of the PC software, the parameters are di-
vided into access levels. A distinction is made between:
1. Hand-held unit - the drive controller is programmed using the hand-held unit.
2. User - the drive control can be programmed with the basic parameters using
the PC software.
3. User - the drive control can be programmed with an advanced selection of pa-
rameters using the PC software.
Commissioning with the MMI hand-held unit
For commissioning with the MMI hand-held unit, see MMI hand-held unit operat-
ing manual [➙ 6].