Installation
5
© Gardner Denver Deutschland GmbH
15
/
74
05.2014 · 610.00260.40.000
Installation
Safety instructions for installation
WARNING
1. Installation may only be performed by appropriately qualified employees who
are trained in the set-up, installation, start-up and operation of the product.
Work performed on the drive control by unqualified staff and non-observance
of warnings may result in serious injury or damage.
2. The device must be grounded in accordance with EN 61140, NEC and other
relevant standards. Mains connections must be hardwired.
Installation requirements
Suitable ambient conditions
Ambient conditions
Altitude of the installation
site:
Up to 1000 m above sea level [3280 ft above sea level] / over 1000 m
[3280 ft] with reduced performance (1% per 100 m [328 ft]) max. 2000 m
[6560 ft], see
Ambient temperature:
-25°C [-13°F] to +50°C [122°F]
(different ambient temperatures may be possible in individual cases) , see
Relative humidity:
≤ 96%, condensation not permitted
Resistance to vibration and
shock:
acc. to FN 942 017 part 4; 5.3.3.3 Combined test 2;
5...200 Hz for sinusoidal oscillation
Electromagnetic compatibil-
ity:
Immune to interference acc. to EN 61800-3
Cooling: Surface
cooling:
sizes A to C: free convection;
size D: with integrated fans
!
Ensure that the housing type (protection type) is suitable for the operating en-
vironment:
1. Ensure that the seal between the motor and the adapter plate is inserted cor-
rectly.
2. All unused cable screw connections must be sealed.
3. Check that the cover of the drive control is closed and bolted down tightly.
Although the drive control can, in principle, be painted later on, the user must
nevertheless check the material compatibility of the intended paint. Failure to
comply with this requirement may eventually result in the loss of the protection
class (particularly in respect to seals and fibre-optic elements). The standard col-
our is black (RAL 9005).
Disassembling the circuit boards (even for the purpose of painting the housing
sections) renders the warranty void!
Mounting points and sealing surfaces must be kept free of paint for purposes of
EMC and grounding!