Parameters – Elmo Rietschle 2FC4...-1CB User Manual
Page 49

Parameters
7
© Gardner Denver Deutschland GmbH
49
/
74
05.2014 · 610.00260.40.000
4.033/4.063
AIx - physical unit
Unit:
Relationship to
parameter:
4.034/4.064
4.035/4.065
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 10
Def: 0
Selection of the different physical variables to be displayed.
0 = %
1 = bar
2 = mbar
3 = psi
4 = Pa
5 = m
3
/h
6 = l/min
7 = °C
8 = °F
9 = m
10 = mm
4.034/4.064
Alx physical minimum
Unit:
Relationship to
parameter:
4.033/4.063
4.035/4.065
Parameter HB:
S. xy
Transfer
status:
2
min: -10000
Intrinsic value
(to be en-
tered!)
max: +10000
Def: 0
Selection of the lower limit of a physical quantity to be dis-
played.
4.035/4.065
AIx - physical maximum
Unit:
Relationship to
parameter:
4.033/4.063
4.035/4.065
Parameter HB:
S. xy
Transfer
status:
2
min: -10000
Intrinsic value
(to be en-
tered!)
max: +10000
Def: 100
Selection of the upper limit of a physical quantity to be dis-
played.
Digital inputs
4.110 – 4.113
DIx inverse
Unit: Integer
Relationship to
parameter:
Parameter HB:
S. xy
Transfer
status:
2
min: 0
Intrinsic value
(to be en-
tered!)
max: 1
Def: 0
Using this parameter, the digital input can be inverted.
0 = inactive
1 = active
7.3.6