Preliminar y, Programming and control, cont’d – Extron Electronics System 5 IP Series User Guide User Manual
Page 94
SIS
™
Programming and Control, cont’d
System 5 IP • SIS
™
Programming and Control
5-38
PRELIMINAR
Y
Command/response table for special function SIS commands, continued
Command
ASCII Command Response
X?
values
(host to MLC)
(MLC to host)
and additional descriptions
Input switching lockouts
Lock out input switching during power on/off
24
X?
* 53 #
PrwLock*
X?
This command prevents input
switching during display warm
up and cool down sequences.
For
X?
,
0 = off/disabled (default)
1 = on/enabled.
Input switching lockout duration
24
X?
* 54 #
IODelay*
X?
Use this command to prevent
input switching for a specific
period after an input has been
switched.
X?
= the lockout period
(0 - 65535 ms in 20 ms steps).
Switching lockout applies only to input buttons.
PINs (personal identification numbers)
Use personal identification numbers (PINs) to allow different types of access to switcher controls. These PINs can be
enabled only during times when the projector or display is powered off.
Enable PINs
24
X?
* 60 #
PINEnable*
X?
For
X?
,
0 = all levels (administrator and
user PINs) are enabled
1 = the administrator PIN is
enabled
2 = PIN-based access is disabled
for all levels (default).
Set a PIN
24
X?
*
Y?
* 61 #
PINNum
X?
*
Y?
This command allows you to set
a PIN for each level of access.
For
X?
,
0 = administrator level
1 = user level.
Y?
= any 4-digit combination of
the numbers 1, 2, 3, 4, and 5.
Default
Y?
values are as
follows:
• administrator = 1524
• user = 0.
Read/display the PIN
24
X?
* 61 #
Y?
For
X?
,
0 = administrator level
1 = user level.
Y?
= the 4-digit PIN.