Preliminar y, Programming and control, cont’d – Extron Electronics System 5 IP Series User Guide User Manual
Page 68
SIS
™
Programming and Control, cont’d
System 5 IP • SIS
™
Programming and Control
5-12
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued)
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)
V
iew power sensor status
8S
8S
X213
If the switcher is connected to an Extr
on
Power Sensor that monitors the pr
ojector/
display
, this tells you whether the display is
still power
ed on.
X213
is as follows:
00 = power sensor is connected and is not
sensing pr
ojector power (detector voltage is
low
, signal pin voltage is high).
01 = power sensor is connected and sensing
p
rojector power (detector voltage is high).
02 = sensor is disconnected or sensor is
connected but sensitivity is too high (voltage
is low at both the detector and signal pin).
V
iew power sensor signal pin status
9S
9S
X214
Power sensor signal pin status:
00 = voltage is low
.
01 = voltage is high.
V
iew
all
voltage & temp. status
11
S
11
S
responses fr
om commands 12S
•
13S
•
14S
•
15S
V
iew all voltages (fr
om main and amplifier
power supplies) and the switcher
’s internal
temperatur
e at once.
Example:
11
S
11S
+1
1.2•-1
1.3•+20.0•104
V
iew + main power supply voltage
12S
12S
+
X206
Display the operating voltage of the
switcher
’s + main power supply
.
V
iew - main power supply voltage
13S
13S
–
X206
Display the operating voltage of the
switcher
’s - main power supply
.
V
iew power amp supply voltage
14S
14S
+
X206
Display the operating voltage of the
amplifier
’s power supply
.
V
iew internal temperatur
e status
15S
15S
X207
Display the internal operating temperatur
e
in degr
ees Fahr
enheit.