Preliminar y, 7 system 5 ip • sis, Programming and control – Extron Electronics System 5 IP Series User Guide User Manual
Page 63
5-7
System 5 IP • SIS
™
Programming and Control
PRELIMINAR
Y
X214
= Power sensor signal pin status
00 = voltage is low (threshold 0.6 V)
01 = voltage is high (threshold 0.7 V)
Leading zeros will be used in responses to
commands that use this variable.
X215
= IR/Serial Output port number
1 = port A
2 = port B
3 = port C
4 = port D
X216
= Display mute or connection status
0 = off/disconnected
1 = on/connected
2 = unknown/unavailable
X200
= Specific input number (0 - 5)
0 = 0 input (no connection)
1 = input 1
2 = input 2
3 = input 3
4 = input 4
5 = input 5
X201
= Video type
1 = RGB (any sync format) (default)
2 = Video (composite video or S-video)
X202
= Audio gain (0 to 30; 0 dB through +30 dB in 1 dB
steps):
0 = 0 dB (default)
1 = 1 dB
2 = 2 dB
...
30 = 30 dB
X203
= Audio attenuation (1 to 40; -1 dB through -40 dB in
1 dB steps):
1 = -1 dB
2 = -2 dB
3 = -3 dB
...
40 = -40 dB
X204
= Audio gain and attenuation value
(-40 to +30 in 1 dB steps)
X205
= Lamp hours elapsed (as a five-digit number, max. =
65535 hours) (the response includes leading
zeros)
X206
= Voltage
X207
= Temperature in degrees Fahrenheit
X208
= Display (projector on/off) status as tracked by the
display driver software
0 = display power is off
1 = display power is on
2 = display is powering down/off (cooling
down)
3 = display is powering up/on (warming up)
4 = disconnected (the display is not responding)
X209
= Front panel lockout (executive mode ) status
0 = off/unlocked (default)
1 = on, disable/lock menu
2 = on, disable/lock menu and buttons
3 = on, disable/lock entire front panel (menu,
buttons, volume control)
X210
= IR/serial port
0 = IR ports (1-4, 0 V-5 V)
1 = RS-232 ports (6-9, ±5 V)
X211
= Status (in hexadecimal characters) of script/
firmware control of button enabling
.
This
variable is 000000## where # represents a
hexadecimal character calculated from a binary
bit map. See page 5-28 for details.
X212
= Status (in hexadecimal characters) of control of
lamp enabling (control of button lights). This
variable is 00000### where # represents a
hexadecimal character calculated from a binary
bit map. See page 5-29 for details.
X213
= Power sensor status:
00
= power sensor is connected and is not
sensing projector power (detector voltage is low,
signal pin voltage is high)
01
= power sensor is connected and is sensing
projector power (detector voltage is high)
02
= power sensor is disconnected or sensor is
connected but the sensitivity is set too high
(voltage is low at both the detector and signal
pin)