Command/response table for sis commands, Preliminar y, Programming and control, cont’d – Extron Electronics System 5 IP Series User Guide User Manual
Page 64: Command/r esponse table for sis commands
SIS
™
Programming and Control, cont’d
System 5 IP • SIS
™
Programming and Control
5-8
PRELIMINAR
Y
Command/r
esponse table for SIS commands
Command
ASCII
(T
elnet)
URL Encoded (W
eb)
Response
Additional description
(host to switcher)
(host to switcher)
(switcher to host)
Input selection
Select an input (audio and video)
X200
!
X200
%21
Chn
X200
Select input
X200
(
X200
= 0, 1, 2, 3, 4, or 5)
(audio and video).
Example
:
4!
4%21
Chn04
Example
: select input 4.
Select an audio input
X200
$
X200
%24
Aud
X200
Select input
X200
audio only
.
Select a video input
X200
&
X200
%26
V
id
X200
Select input
X200
video only
.
V
iew the curr
ent audio channel
$
%24
X200
V
iew the curr
ent video channel
&
%26
X200
The switcher r
esponds with an E22 (busy) err
or if these commands ar
e sent during I/O switching lockout (command 54#) or during
power on/off switching lockout (53#).
Switching audio separately fr
om video or video separately fr
om audio is often called “audio br
eakaway”. For the System 5 IP
, S
IS commands offer the only means for br
eakaway
.
Display (pr
ojector) power
T
urn display power on
1P
1P
Pwr
X208
On (discr
ete).
T
urn display power of
f
0P
0P
Pwr
X208
O
ff (discr
ete).
V
iew display power status
P
P
X208
Show the display power status.
X208
= display power status
0 = of
f
1 = on
2 = powering of
f/down
3 = powering on/up
Example
:P
P
2
The display is powering of
f.
Set power status
24
X208
*0P
X208
%2A0P
Pwr
X208
This command is used only by scripts. It
p
rovides a way to set the power status to
match the actual state of the pr
ojector
.
Display mute
T
urn display mute on
1M
1M
Mut1
Mute.
T
urn display mute of
f
0M
0M
Mut0
Unmute.
V
iew display mute status
M
M
X216
Show display mute status:
X216
= 0 (of
f/disconnected), 1 (on/
connected), or 2 (unknown/unavailable).
Set mute status
24
X216
*0M
X216
%2A0M
Mut
X216
This command is used only by scripts. It
p
rovides a way to set the status to match the
actual state of the pr
ojector or display
.