beautypg.com

Alarms and snmp, Overview — alarms, Overview – Extron Electronics VN-Matrix 300 User Guide User Manual

Page 65: Alarms

background image

VN-Matrix 300 • Alarms and SNMP

59

Alarms and SNMP

This section provide the following:

z

Overview — Alarms

z

Alarms Page

z

Overview — SNMP

z

SNMP Trap Destinations

Overview

Alarms

The VN-Matrix 300 is configured to generate alarms for range of error conditions. A list of
these error conditions and their meanings are presented on the following pages.
Alarms can be monitored at a number of locations throughout the WEB GUI:

z

Alarms

page

In the list immediately below the

Filter Settings

box. This details the alarm

conditions that are currently active on the system.

z

Alarm Logs

page

In the list immediately below the

Filter Settings

box. This provides a historical log of

when an alarm condition was raised and cleared.

z

Device list

page (see figure

15

)

Where a Traffic light symbol in the Status Column is used to represent the status of a
device.

z

In the top right hand corner of each page in the GUI.
Where the device status and system status is displayed.

In addition the red LED located on the front panel of the VN-Matrix 300 illuminates
whenever a critical alarm is triggered.
Alarm conditions, once triggered, will be remain active until the error that caused it has
cleared and then for a further 5 seconds.