Video and audio data, Switched network configuration, example 1, Example 1 – Extron Electronics VN-Matrix 300 User Guide User Manual
Page 27

VN-Matrix 300 • Installation and Basic Setup Procedures
21
Video and Audio Data
Video and audio data may be transported over either of the NICs on the VN-Matrix 300 unit
and are independent of the system control data.
NOTE: The browser is accessible via either network port on the unit that is configured
as the controller.
Switched Network Configuration, Example 1
NOTES: In this example, two VN-Matrix 300 units are configured to work across a
switched network.
•
Unit 1 is configured as the controller, on IP address 172.28.0.1.
This unit serves the management interface (GUI).
•
The browser (control) PC may be connected to either NIC.
System control data is always sent over the 172.28.x.x network
•
Image data is configured to run over NIC 1 (the RJ45 connector).
This is defined in the management interface, described later.
NIC2:192.168.0.1
NIC1:172.28.0.1
NIC2:192.168.0.2
NIC1:172.28.0.2
Switch
Local NMS server
172.28.0.3
Browser
172.28.0.4
Unit 1
Unit 2
Controller
Browser (NIC2)
192.168.0.3
Switch
Browser address
192.168.0.1
Browser address
172.28.0.1
Unit 1
Network Port 1 (RJ45)
Network Port 2 (SFP)
0
Speed/Duplex:auto_10_100_1000
10
Speed/Duplex:Fiber_fixed_1000
1
Boot method: static [dhcp]
11
Boot method: static [dhcp]
2
Address: 172.28.0.1
12
Address: 192.168.0.1
3
Netmask: 255.255.0.0
13
Netmask: 255.255.255.0
4
Gateway:
14
Gateway:
5
Broadcast:
15
Broadcast:
6
Mtu: 1500
16
Mtu: 1500
7
Controller ip: 172.28.0.1
8
Controller port: 5432
18
Webserver port: 80
9
Exit