Unit-initiated messages, Unit-initiated messages -5, Remote control, cont’d – Extron Electronics FOX 500 DVI Tx User Guide User Manual
Page 27
![background image](/manuals/311736/27/background.png)
FOX 500 Tx/Rx • Remote Control
Remote Control, cont’d
4-4
FOX 500 Tx/Rx • Remote Control
4-5
]
= CR/LF (carriage return/line feed)
•
= space
X!
= Mute/auto image/front panel lock status
0 or 1 (0=off and 1=on)
X@
= Output sync format
0 = RGBHV
1 = RGsB
X#
= Output sync polarity
0 = follow input
1 = force sync to negative
X$
= Horizontal and vertical position
0 to 255
X%
= Horizontal start
0 to 255
X^
= Pixel phase
0 to 31
X&
= Total pixels
± 255 of the default value
X*
= Sync frequency
xxx.xx (frequency in kHz [H]
or Hz [V])
X(
= Memory preset number
1 to 30
X1)
= Audio gain adjustment range
0 to 10
X1!
= Audio attenuation adjustment range
0 to 18
X1@
= Audio level adjustment range
-18.0 to +10.0 (in 1.0 dB steps)
X1#
= Output level
0 = consumer
1 = professional
X1$
= Test pattern
0 = none
1 = Color Bars
2 = grayscale
3 = alternating pixels
X1%
= Firmware version
v
.vv
X1^
= Link/input status
0 = link or input not detected
1 = link or input detected
X1&
= Mode
SM = singlemode
MM = multimode
X1*
= Transmitter or receiver
Tx = transmitter
Rx = receiver
X1(
= Resolution
1 = 1920 x 1200
2 = 800 x 600
3 = 1024 x 768
4 = 1280 x 768
5 = 1280 x 1024
6 = 1365 x 768
7 = 1366 x 768
8 = 1400 x 1050
9 = 1600 x 1200
10 = 480p
11 = 576p
12 = 720p
13 = 1080i
14 = 1080p
15 = 640 x 480
X2)
= Refresh rate
1 = 50 Hz
2 = 60 Hz
X2!
= DDC rotary switch position
00 to 15 (= 0 to F hex)
X2@
= Link 2 enable
0 = disable
1 = enable (default)
X2#
= Internal temperature (Fahrenheit and Celsius) nnnF•nnC
Unit-initiated messages
When a local event, such as a front panel operation or error
condition, occurs, the unit responds by sending a message to the
host. The unit-initiated messages are listed below:
(c) COPYRIGHT 2007, EXTRON ELECTRONICS FOX 500 Tx,
Vx.xx, 60-746-xx]]
- or -
(c) COPYRIGHT 2007, EXTRON ELECTRONICS FOX 500 Rx,
Vx.xx, 60-746-xx]]
- or -
(c) COPYRIGHT 2007, EXTRON ELECTRONICS FOX 500 DVI Tx,
Vx.xx, 60-859-xx]]
- or -
(c) COPYRIGHT 2007, EXTRON ELECTRONICS FOX 500 DVI Rx,
Vx.xx, 60-859-xx]]
The connected unit issues the appropriate copyright message
(above) when it first powers on. Vx.xx is the firmware version
number, 60-xxx-xx is the connected unit's part number.
Reconfig
]
The unit sends the Reconfig message whenever the video input
signal to the transmitter is changed.
Hph
X$]
The unit sends the Hph message whenever the output's
horizontal position is shifted.
Vph
X$]
The unit sends the Vph message whenever the output's vertical
position is shifted.
Hst
X%]
The unit sends the Hst message whenever the output's
horizontal start is shifted.
Tpx
X&]
The unit sends the Tpx message whenever the total pixels
variable is changed.
Phs
X^]
The unit sends the Phs message whenever the pixel phase
variable is changed.