Rear panel serial ports connection, Alarm outputs connection, See "rear panel serial ports connections – Extron Electronics FOX 500 DVI Tx User Guide User Manual
Page 17: Captive screw connector, See "rear panel serial, To wire this connector, Rear panel serial ports connections, Installation, cont’d
FOX 500 Tx/Rx • Installation
Installation, cont’d
2-16
FOX 500 Tx/Rx • Installation
2-17
N
Use only cables specifically intended for DVI or HDMI
interfaces. Use of non-DVI or non-HDMI cables or
modified cables can result in a missing video output.
Rear panel serial ports connection
Do not tin the wires!
Controlling
Device
Ground ( )
Receive (Rx)
Transmit (Tx)
Ground ( )
Receive (Rx)
Transmit (Tx)
Bidirectional
RS-232
OVER FIBER
Tx Rx
NA
REMOTE
RS-232
ALARM
Tx Rx
1 2
Function
Pin
TX
RX
Gnd
Transmit data
Receive data
Signal ground
NOTE
For the RS-232 Over Fiber port, only cross the Tx and
Rx lines once between the source and the target.
Figure 2-10 — RS-232 connectors
N
The RS-232 Over Fiber port is for transmission of serial
signals, such as projector control signals, between the
transmitter and receiver.
The Remote RS-232 port is for remote control of the
transmitter and receiver.
N
The length of exposed wires is critical. The ideal length
is 3/16" (5 mm).
•
If the stripped section of wire is longer than 3/16", the
exposed wires may touch, causing a short circuit.
•
If the stripped section of wire is shorter than 3/16",
wires can be easily pulled out even if tightly fastened
by the captive screws.
N
The rear panel Remote RS-232 port is active only if the
front panel Configuration port is not active. If an active
front panel configuration connection is made, the rear
panel Remote RS-232 port becomes inactive.
Alarm outputs connection
REMOTE
RS-232
ALARM
Tx Rx
1 2
Pin 1 and pin 2 are
shorted together when
no light is detected.
Do not tin the wires!
Figure 2-11 — Alarm connector
N
The length of exposed wires is critical. The ideal length
is 3/16" (5 mm).
•
If the stripped section of wire is longer than 3/16", the
exposed wires may touch, causing a short circuit.
•
If the stripped section of wire is shorter than 3/16",
wires can be easily pulled out even if tightly fastened
by the captive screws.