beautypg.com

Rear panel serial ports connection, Alarm outputs connection, See "rear panel serial ports connections – Extron Electronics FOX 500 DVI Tx User Guide User Manual

Page 17: Captive screw connector, See "rear panel serial, To wire this connector, Rear panel serial ports connections, Installation, cont’d

background image

FOX 500 Tx/Rx • Installation

Installation, cont’d

2-16

FOX 500 Tx/Rx • Installation

2-17

N

Use only cables specifically intended for DVI or HDMI

interfaces. Use of non-DVI or non-HDMI cables or

modified cables can result in a missing video output.

Rear panel serial ports connection

Do not tin the wires!

Controlling

Device

Ground ( )
Receive (Rx)
Transmit (Tx)

Ground ( )

Receive (Rx)

Transmit (Tx)

Bidirectional

RS-232

OVER FIBER

Tx Rx

NA

REMOTE

RS-232

ALARM

Tx Rx

1 2

Function

Pin

TX

RX

Gnd

Transmit data
Receive data
Signal ground

NOTE

For the RS-232 Over Fiber port, only cross the Tx and

Rx lines once between the source and the target.

Figure 2-10 — RS-232 connectors

N

The RS-232 Over Fiber port is for transmission of serial

signals, such as projector control signals, between the

transmitter and receiver.

The Remote RS-232 port is for remote control of the

transmitter and receiver.

N

The length of exposed wires is critical. The ideal length

is 3/16" (5 mm).

If the stripped section of wire is longer than 3/16", the

exposed wires may touch, causing a short circuit.

If the stripped section of wire is shorter than 3/16",

wires can be easily pulled out even if tightly fastened

by the captive screws.

N

The rear panel Remote RS-232 port is active only if the

front panel Configuration port is not active. If an active

front panel configuration connection is made, the rear

panel Remote RS-232 port becomes inactive.

Alarm outputs connection

REMOTE

RS-232

ALARM

Tx Rx

1 2

Pin 1 and pin 2 are
shorted together when
no light is detected.

Do not tin the wires!

Figure 2-11 — Alarm connector

N

The length of exposed wires is critical. The ideal length

is 3/16" (5 mm).

If the stripped section of wire is longer than 3/16", the

exposed wires may touch, causing a short circuit.

If the stripped section of wire is shorter than 3/16",

wires can be easily pulled out even if tightly fastened

by the captive screws.