Specifications

Appendix O

YSI Incorporated

Environmental Monitoring Systems Operations Manual

O-11

pH

Sensor Type...........Glass combination electrode

Range.....................0 to 14 units

Accuracy................+/- 0.2 units

Resolution..............0.01 units

Temperature Range -5 to 50 C

Depth……………200 meters

ORP

Sensor type............ Platinum button

Range.....................-999 to +999 mV

Accuracy................+/-20 mV in redox standard solutions

Resolution...............0.1 mV

Temperature Range -5 to 60 C

Depth……………200 meters

Turbidity

Sensor type............ Optical, 90

scatter, with mechanical cleaning

Range..................... 0 to 1000 NTU

Accuracy................+/- 2% of the reading or 0.3 NTU (whichever is greater),

in YSI AMCO-AEPA standards

Resolution...............0.1 NTU

Temperature Range -5 to 50 C

Depth…………… 61 meters

Chlorophyll

Sensor type............ Optical, fluorescence, with mechanical cleaning

Range..................... Approximately 0 to 400 µg/L Chl; 0-100 Relative Fluorescence Units (RFU)

Accuracy................ No specification provided

Linearity................ R2 > 0.9999 for serial dilution of Rhodamine WT solution from 0 to 500 ug/L

Detection Limit…..Approximately 0.1 ug/L Chl (determined using cultures of Isochrysis sp. and chlorophyll a

concentration determined through extractions).

Resolution...............0.1 µg/L Chl; 0.1 RFU

Temperature Range -5 to 50 C

Depth…………… 61 meters

Phycocyanin-Blue-green Algae (BGA-PC)

Sensor type............ Optical, fluorescence, with mechanical cleaning

Range..................... Approximately 0 to 280,000 cells/mL of BGA (See Principles of Operation section for

explanation of estimate); 0-100 Relative Fluorescence Units (RFU)

Accuracy................ No specification provided.

Linearity................ R2 > 0.9999 for serial dilution of Rhodamine WT solution from 0 to 400 ug/L

Detection Limit...... Approximately 220 cells/mL. Estimated from cultures of Microcystis aeruginosa

Resolution...............1 cell/mL; 0.1 RFU

Temperature Range -5 to 50 C

Depth…………… 61 meters

Phycoerythrin-Blue-green Algae (BGA-PE)

Sensor type............ Optical, fluorescence, with mechanical cleaning

Range..................... Approximately 0 to 200,000 cells/mL of BGA (See Principles of Operation section for

explanation of estimate); 0-100 Relative Fluorescence Units (RFU)

Accuracy................ No specification provided.

Linearity................ R2 > 0.9999 for serial dilution of Rhodamine WT solution from 0 to 8 ug/L

Detection Limit...... Approximately 450 cells/mL. Estimated from cultures of a Synechococcus species.

Resolution...............1 cell/mL; 0.1 RFU

Temperature Range -5 to 50 C

Depth…………… 61 meters