Physical & environmental approvals, Table 31 - mechanical approvals, 0 physical & environmental approvals – B&B Electronics APXN-Q5428 - User Manual User Manual
Page 105

AirborneM2M™ Users Guide
B&B Electronics, Inc.
1/9/2014
105
18.0
Physical & Environmental Approvals
The device has passed the following primary physical and environmental tests. The test
methods referenced are defined in SAE J1455 Aug1994.
Table 31 - Mechanical Approvals
Test
Reference
Conditions
Temperature Range
(Operational)
Table 1B, Type 2b
-40°C to +85°C
Temperature Range (Non-
Operational)
-40°C to +85°C
Humidity
Sect 4.2.3
0-95%RH @ 38°C condensing
Fig 4a – 8 hours active humidity cycle
Altitude
Sect 4.8
Operational: 0-12,000ft (62 KPa absolute pressure)
Non-operational: 0-40,000ft (18.6 KPa absolute
pressure)
Vibration
Sect 4.9
Operational: 2.4 Grms, 10-1K Hz, 1hr per axis
Non-operational: 5.2 Grms, 10-1K Hz, 1hr per axis
Shock
Sect 4.10
Operational: 20Gs MAX, 11ms half-sine pulse
Product Drop
Sect 4.10.3.1
1m onto concrete, any face or corner, 1 drop
Packaging Drop
Sect 4.10.2.1
32 inches onto concrete on each face and corner.
Packaged in ‘for transit’ configuration.
Test reports are available from B&B Electronics Technical Support, please contact
directly for the latest documentation.