SR: STATUS REGISTER (Address=14 Hex)

(MSB)

(LSB)

RA1

RA0

RLOS

BED

BCOF

BECOF

SYNC

SYMBOL

POSITION

NAME AND DESCRIPTION

SR.7

Not Assigned. Could be any value when read.

RA1

SR.6

Receive All Ones. Set when 32 consecutive ones are received; allowed to
be cleared when a zero is received.

RA0

SR.5

Receive All Zeros. Set when 32 consecutive zeros are received; allowed
to be cleared when a one is received.

RLOS

SR.4

Receive Loss Of Sync. Set when the device is searching for synchroniza-
tion. Once sync is achieved, will remain set until read.

BED

SR.3

Bit Error Detection. Set when bit errors are detected.

BCOF

SR.2

Bit Counter Overflow. Set when the 32–bit BCR overflows.

BECOF

SR.1

Bit Error Count Overflow. Set when the 32–bit BECR overflows.

SYNC

SR.0

Sync. Real time status of the synchronizer (this bit is not latched). Will be
set when the incoming pattern at RDATA matches for 32 consecutive bit
positions. Will be cleared when 6 or more bits out of 64 are received in error
(if PCR.2 = 0).

IMR: INTERRUPT MASK REGISTER (Address=15 Hex)

(MSB)

(LSB)

RA1

RA0

RLOS

BED

BCOF

BECOF

SYNC

SYMBOL

POSITION

NAME AND DESCRIPTION

IMR.7

Not Assigned. Should be set to zero when written to.

RA1

IMR.6

Receive All Ones.
0 = interrupt masked
1 = interrupt enabled

RA0

IMR.5

Receive All Zeros.
0 = interrupt masked
1 = interrupt enabled

RLOS

IMR.4

Receive Loss Of Sync.
0 = interrupt masked
1 = interrupt enabled

BED

IMR.3

Bit Error Detection.
0 = interrupt masked
1 = interrupt enabled

BCOF

IMR.2

Bit Counter Overflow.
0 = interrupt masked
1 = interrupt enabled

BECOF

IMR.1

Bit Error Count Overflow.
0 = interrupt masked
1 = interrupt enabled

SYNC

IMR.0

Sync.
0 = interrupt masked