Electrical characteristics (continued) – Rainbow Electronics MAX5965B User Manual
Page 5
MAX5965A/MAX5965B
High-Power, Quad, Monolithic, PSE Controllers
for Power over Ethernet
_______________________________________________________________________________________
5
ELECTRICAL CHARACTERISTICS (continued)
(V
AGND
= 32V to 60V, V
EE
= 0V, V
DD
to V
DGND
= +3.3V, all voltages are referenced to V
EE
, unless otherwise noted. Typical values are at
V
AGND
= +48V, V
DGND
= +48V, V
DD
= (V
DGND
+ 3.3V), T
A
= +25°C. Currents are positive when entering the pin and negative other-
wise.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
LOAD DISCONNECT
DC Load Disconnect
Threshold
V
DCTH
Minimum V
SENSE
allowed before disconnect
(DC disconnect active), V
OUT_
= 0V
2.5
3.75
5.0
mV
AC Load Disconnect
Threshold
I
ACTH
Current into DET_, for I < I
ACTH
the port
powers off, ACD_EN_ bit = H; V
OSC_IN
=
2.2V, MAX5965B (Note 6)
285
320
360
µA
Oscillator Buffer Gain
A
OSC
V
DET_
/V
OSC
, ACD_EN_ bit = H, MAX5965B
2.9
3.0
3.1
V/V
OSC Fail Threshold
V
OSC_FAIL
Port does not power on if V
OSC
< V
OSC_FAIL
and ACD_EN_ bit is high, MAX5965B (Note 7)
1.8
2.2
V
OSC Input Impedance
Z
OSC
OSC input impedance when all the ACD_EN_
are active, MAX5965B
100
k
Ω
Load Disconnect Timer
t
DISC
Time from V
SENSE
< V
DCTH
to gate shutdown
(Note 8)
300
400
ms
DETECTION
Detection Probe Voltage
(First Phase)
V
DPH1
AGND - V
DET_
during the first detection
phase
3.8
4
4.2
V
Detection Probe Voltage
(Second Phase)
V
DPH2
AGND - V
DET_
during the second detection
phase
9.0
9.3
9.6
V
Current-Limit Protection
I
DLIM
V
DET_
= AGND, during detection, measure
current through DET_
1.5
1.8
2.2
mA
Short-Circuit Threshold
V
DCP
If AGND - V
OUT
< V
DCP
after the first
detection phase a short circuit to AGND is
detected
1
V
Open-Circuit Threshold
I
D_OPEN
First point measurement current threshold for
open condition
12.5
µA
Resistor Detection Window
R
DOK
(Note 9)
19.0
26.5
k
Ω
Detection rejects lower values
15.2
Resistor Rejection Window
R
DBAD
Detection rejects higher values
32
k
Ω
CLASSIFICATION
Classification Probe Voltage
V
CL
V
AGND
- V
DET_
during classification
16
20
V
Current-Limit Protection
I
CILIM
DET_ = AGND, during classification
68
80
mA
Class 0, Class 1
5.5
6.5
7.5
Class 1, Class 2
13
14.5
16
Class 2, Class 3
21
23
25
Class 3, Class 4
31
33
35
Classification Current
Thresholds
I
CL
Classification current
thresholds between
classes
Class 4, Class 5
45
48
51
mA