Table 32. miscellaneous configurations 2, Table 34a. icut registers 1 and 2, Table 34b. icut registers 3 and 4 – Rainbow Electronics MAX5965B User Manual
Page 41: Table 33. current-limit scaling register
MAX5965A/MAX5965B
High-Power, Quad, Monolithic, PSE Controllers
for Power over Ethernet
______________________________________________________________________________________
41
The three ICUT_ bits (Tables 34a and 34b) allow pro-
gramming of the current-limit and overcurrent thresholds
in excess of the IEEE 802.3af standard limit. The
MAX5965A/MAX5965B can automatically set the ICUT
register or can be manually written to by the software
(see Table 3).
Class 1 and 2 limits can also be programmed by soft-
ware independently from the classification status. See
Table 3. A reset or power-up sets R2Ah = R2Bh = 00h.
Table 32. Miscellaneous Configurations 2
ADDRESS = 29h
SYMBOL
BIT
R/W
DESCRIPTION
7
—
Reserved
6
—
Reserved
5
—
Reserved
4
—
Reserved
3
—
Reserved
Reserved
2
—
Reserved
1
R/W
IVEE[1]
IVEE
0
R/W
IVEE[0]
Table 34a. ICUT Registers 1 and 2
ADDRESS = 2Ah
SYMBOL
BIT
R/W
DESCRIPTION
Reserved
7
—
Reserved
6
R/W
ICUT2[2]
5
R/W
ICUT2[1]
ICUT2
4
R/W
ICUT2[0]
Reserved
3
—
Reserved
2
R/W
ICUT1[2]
1
R/W
ICUT1[1]
ICUT1
0
R/W
ICUT1[0]
Table 34b. ICUT Registers 3 and 4
ADDRESS = 2Bh
SYMBOL
BIT
R/W
DESCRIPTION
Reserved
7
—
Reserved
6
R/W
ICUT4[2]
5
R/W
ICUT4[1]
ICUT4
4
R/W
ICUT4[0]
Reserved
3
—
Reserved
2
R/W
ICUT3[2]
1
R/W
ICUT3[1]
ICUT3
0
R/W
ICUT3[0]
Table 33. Current-Limit Scaling Register
IVEE[1:0]
(ADDRESS = 29h)
CURRENT LIMIT
(%)
00
Default
01
-5
10
-10
11
-15
The IVEE bits enable the current-limit scaling (Table
32). This feature is used to reduce the current limit for
systems running at higher voltage to maintain the
desired output power. Table 33 sets the current-limit
scaling register. A reset or power-up sets R29h = 00h.