Gas sampling and gas conditioning technology

4-2.1.3-ME

8

TECHNICAL DATA

Portable Gas Conditioning Unit

Type

CSS-M

Sample outlet dew point

range of adjustment: +2 °C ..... +15 °C, factory setting: +5 °C

Dew point stability

at constant conditions < ± 0,1 °C

Sample inlet temperature

**max. 80°C**

Gas inlet water vapour saturation

**max. +50°C

Gas flow rate

**max. 70l/h

Ambient temperature

**+10°C to +45°C

Air humidity

75% year’s average, rare and slight dewing of

95% on 30

days per year admissible

Storage temperature

-25°C to +65°C

Pressure

0,7bar to 1,4bar abs.*

Total cooling capacity

max. 40kJ/h

Number of gas inlets

1

Number of gas outlets

1*

Sample gas connections

Hose connection 4/6 mm

Material medium-touched parts

Glass, PVDF, PVC, Novoprene

®

, FPM, PPH

Ready for operation

Approx. 10 min.

Mains power supply

230V 50Hz ± 10% or 115V 60Hz ± 10%

Power consumption

max. 240VA

Fuse protection

4A, time-lag, 5x20mm

Electrical mains supply

Cold appliance plug with 2m cable

Case protection

IP20

(EN 60529)

Housing version

Sheet steel case

Case dimensions (H x W x D)

177mm x 220mm x 300mm

Weight

Approx. 11kg

PVDF=Polyvinylidenefluoride
PVC=Polyvinyl chloride
FPM=Fluor caoutchouc
PPH=Polypropylene hard


Specifications for components see appendix

* Standard

Maximum values in technical datas must be rated in consideration of total cooling capacity at 25 °C