beautypg.com

Pump mp47 .../d, Receipt of goods and storage, Figure 6 – M&C TechGroup MP47_D Operator's manual User Manual

Page 12: Pump mp47 .../d with flow sensor

background image

12

Gas sampling and gas conditioning technology

6-1.1.1-ME

12

FLOW SENSOR LPH 125-1-A-SPST INCL. CONNECTION SET MP47 .../D
MOUNTED ON PUMP MP47 .../D

The optional available flow sensor LPH is provided with a mounting clip, 2x male connectors 1/8”- 2
mm and 0,5 m PTFE tube 1 x 2 mm.


ø 28

51


Figure 6 Pump MP47 .../D with flow sensor

Fitting position: vertical
Alarm level: 7 l/hr
Switching function: NC or NO depending on mounting position
NC = lead of flow sensor in position at the top
Contact rating: DC max. 200 V, 50 W, 1 A; AC max. 150 V, 70 VA, 0,7 A
Material: Acrylic, PTFE, nickel-plate brass
As monitoring gas, it can be used N

2

or with max. 1,7 bar,

depending on the application (at least, however, sample pressure plus 0,2 bar compressed air).
In case of a correctly functioning diaphragm pump, no monitoring gas will be consumed.



13

RECEIPT OF GOODS AND STORAGE

Please take the sample pump and possible special accessories carefully out of the packaging
material immediately after arrival, and compare the goods with the items listed on the delivery
note!

Check the goods for any damage caused during delivery and, if necessary, notify your trans-
port insurance company without delay of any damage discovered.

N O T E !


The equipment should be stored in a protected, frost-free room!

LPH-7 l/hr

1/8“ NPT f