Description, Reception and storage, Figure 1 – M&C TechGroup FSS-..._H350 Operator's manual User Manual
Page 8: Heated filter fss-../h350, 9description, 10 reception and storage
8
Gas sampling and gas conditioning technology
5-2.1.5-ME
9
DESCRIPTION
The M&C filter FSS../H350 is mounted thermally isolated on a plate. The stainless steel filter body with
integrated filter element, alternatively of ceramic, stainless steel or special spun glass, is completely
covered by a heated metal enclosure.
The high capacity heating element is controlled by an incorporated compact capillary sensor
thermostat in a temperature range of +50 °C to 350 °C. The thermostat is equipped with an
temperature limiter switch with reset key, releasing at 30 °C above set-temperature, and a voltage-free
low temperature alarm contact at 30 °C below set-temperature. In order to avoid cold spots, the
welded connecting fittings are heated up with the filter by means of two heat conducting jaws.
Outside the lagged cap a junction box is mounted which contains the thermostat as well as the
terminals for electrical connection. Two brackets fix the heated lines. The complete conception
guarantees a safe operation and a simple maintenance. No tools are needed for replacing the filter
element, during the heated sample lines remain in their position.
Figure 1 Electrical heated universal filter FSS-../H350
10
RECEPTION AND STORAGE
The device is a complete pre-installed unit.
Carefully inspect the device and any special accessories included with it immediately on arrival
by removing them from the packing and checking for missing articles against the packing list!
Check the items for any damage in transit and, if required, inform the shipping insurance
company immediately of the damage found!
C A R E !
The device must be stored in a weather protected frost-free area!
Filter element
Junction box
with thermostat
Connecting
fittings
Heat
conducting
jaws
Lagged cap
Brackets
Alarm-
contact
Power
Sample IN
Sample OUT