VarID Configuration File

The VarID parameters are defined in a configuration file. This file, named varid.ini, is
located in the C:\LSMCE\DATA directory.

The file has the following syntax:

;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;

; VARID settings

;------------------------------

;Parameter values and [default]

;

; Uniqueness= [Local] or Global

; Length= [32] or 8

; Format= [ASCII] or Binary

; Visibility= [], 1..29,*

; default= empty is converted to local XT Net

number

; * for all XNet

;

;------------------------------

Uniqueness=Local

Length=32

Format=ASCII

1=

2=

3=

4=

5=

6=

;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;

Uniqueness

Description

This field is not relevant on this type of server.

Value

The value is forced to 'Local', which means that the VarID is
unique at the server level.

Length

Description

Specifies whether the VarID has a fixed length of 8 bytes or a
variable length of 32 bytes.

Values

8, fixed length.

32, variable length.

Default value

32