Appendix H Internal SPTGEN

P-2602H(W)(L)-DxA User’s Guide

426

Internal SPTGEN File Modification - Important Points to Remember

Each parameter you enter must be preceded by one “=”sign and one space.
Some parameters are dependent on others. For example, if you disable the Configured field in
menu 1 (see

Figure 254 on page 425

), then you disable every field in this menu.

If you enter a parameter that is invalid in the Input column, the ZyXEL Device will not save
the configuration and the command line will display the Field Identification Number.

Figure

255 on page 426

, shown next, is an example of what the ZyXEL Device displays if you enter a

value other than “0” or “1” in the Input column of Field Identification Number 1000000
(refer to

Figure 254 on page 425

).

Figure 255 Invalid Parameter Entered: Command Line Example

The ZyXEL Device will display the following if you enter parameter(s) that are valid.

Figure 256 Valid Parameter Entered: Command Line Example

Internal SPTGEN FTP Download Example

1 Launch your FTP application.
2 Enter "

bin

". The command “

bin

” sets the transfer mode to binary.

3 Get "

rom-t

" file. The command “

get

” transfers files from the ZyXEL Device to your

computer. The name “

rom-t

” is the configuration filename on the ZyXEL Device.

4 Edit the "

rom-t

" file using a text editor (do not use a word processor). You must leave

this FTP screen to edit.

field value is not legal error:-1
ROM-t is not saved, error Line ID:10000000
reboot to get the original configuration
Bootbase Version: V2.02 | 2/22/2001 13:33:11
RAM: Size = 8192 Kbytes
FLASH: Intel 8M *2

Please wait for the system to write SPT text file(ROM-t)...
Bootbase Version: V2.02 | 2/22/2001 13:33:11
RAM: Size = 8192 Kbytes
FLASH: Intel 8M *2