ZyXEL Communications omni.net Plus User Manual
Page 165

Technical Reference for ZyXEL omni.net series
B-13
All the Following Commands Require a 'AT' Prefix
S Com.
bit
dec
hex
Function and description
+Def./Ref.
S84= bit dec
hex
0-2
Embedded Protocol Analyzer control.
CCn
0
1
1
Capture DTE-DCE interface protocol information.
1
2
2
Capture B-channel (X.75 or V.120) frames.
2 4 4 Capture
D-channel
protocol
information.
3
0
0 (*)
Display S register value in decimal format.
8
8
Display S register value in hex format.
4
0 (*)
0
Indicate Caller ID after the 1st RING message.
16
10
Disable Caller ID indication.
5
0
0
POTS port 1 has higher priority for answering an analog call.
&L0
32
20
POTS port 2 has higher priority for answering an analog call.
&L1
S85= bit dec
hex
0
0
0
Call Bumping function disabled.
CE0
1
1 (*)
Call Bumping function enabled.
CE1
1-6
0 (*)
Add-persist time interval.
KAxn
7
0
0 (*)
S85b1-6 is in Second unit.
KASn
128
80
S85b1-6 is in Minute unit.
KAMn
S87= bit dec
hex
0
0 (*)
0
Enable POTS port 1 to receive global calls.
1
1
Disable POTS port 1 to receive global calls.
1
0 (*)
0
Enable POTS port 2 to receive global calls.
2
2
Disable POTS port 2 to receive global calls.
2
0 (*)
0
CHAP/PAP for authentication conversion.
4
4
PAP only for authentication conversion.
4
0 (*)
0
Result code 46 for X7 is CONNECT 112K/..
Result code 47 for X7 is CONNECT 128K/..
16
10
Result code 46 for X7 is CONNECT 112000/..
Result code 47 for X7 is CONNECT 128000/..
5-6
0 (*)
0
Bundle connection is disabled.
&Jn