beautypg.com

Source]:roscillator:source, Source[1|2]]:sweep:htime – Tektronix AFG3000 User Manual

Page 151

background image

Syntax and Commands

AFG3000 Series Arbitrary/Function Generators Reference Manual

3-77

[SOURce]:ROSCillator:SOURce

This command sets the reference clock to either internal or external.

Group

Source

Syntax

[SOURce]:ROSCillator:SOURce {INTernal|EXTernal}

[SOURce]:ROSCillator:SOURce?

Arguments

INTernal means that the reference clock is set to internal.

EXTernal means that the reference clock is set to external.

Returns

INT|EXT

Examples

SOURce:ROSCillator:SOURce INTernal
selects the internal clock reference.

[SOURce[1|2]]:SWEep:HTIMe

This command sets or queries the sweep hold time. Hold time represents the
amount of time that the frequency must remain stable after reaching the stop
frequency.

Group

Source

Syntax

[SOURce[1|2]]:SWEep:HTIMe {|MINimum|MAXimum}

[SOURce[1|2]]:SWEep:HTIMe? {MINimum|MAXimum}

Arguments

::=[]
where
is the hold time in seconds.
::=[ns |

µs | ms | s]

Returns

Examples

SOURce1:SWEep:HTIMe 1ms
sets the CH 1 hold time to 1 ms.